Consulting and Professional Services

NOT EVERY CALL
IS A QUOTE REQUEST

Tangent Steel Structures works with architects, structural engineers, developers, general contractors and owners before there is anything to price: sizing and system selection, site-specific snow, wind and seismic loads under the 2024 IBC, plan and specification review, bid invites, component specs and samples, and reaction loads for foundation design. Design consultations and plan reviews during bidding are free. We do this as your steel building supplier: we are not the architect, the engineer of record, the general contractor or the erector. Ask us anything on the question form or call (801) 829-1642.

Ask a Question Codes and Loads for Your Site

What we help with

Design consultation

Width, length, eave height, clear span, door and opening placement, lean-tos and mezzanines, and which system fits: HyperSteel cold-formed, Simplisteel rigid frame, or a custom engineered Metallic building. We will tell you when a pole barn is the better buy.

Codes and loads

Site-specific ground snow, wind, seismic category, elevation and frost depth for the exact lot, under the 2024 IBC and ASCE 7-22 in Utah and the 2018 IBC in Idaho. Which value the building department will accept, and what it does to the frame. Look up your own with the free ASCE tool, anywhere in the US.

Architect and engineer questions

Frame reactions and anchor bolt plans for your foundation engineer, deflection criteria, bracing locations and what they mean for openings, facade attachment (brick, stone, stud walls), insulation systems and energy code paths.

Plan and spec review

Send the architectural and structural set and the spec section. We read them against the manufacturer's scope, flag conflicts before they become change orders, and return a scope letter with inclusions, exclusions and questions. This is a supplier's scope review; we do not stamp or approve design documents.

Bid invites, design-build and developers

Budget numbers for pro formas, hard bids from plans, value engineering between cold-formed and red iron, lead times for schedules, and coordination with your GC or erector. Send the invite to sales@tangentsteelstructures.com or use the form.

Specs and samples

Panel profiles, gauges and finishes, trim details, insulation systems, doors and windows, color charts and panel samples, and the manufacturer's standard specifications for your project manual.

How a consultation works

  1. Tell us what you have. An address and a use is enough to start. Plans, a spec section or a bid invite are better. Use the question form and pick the closest reason, or email sales@tangentsteelstructures.com.
  2. We pull the loads and read the documents. Site-specific snow, wind and seismic for the lot, and a scope read of whatever you sent.
  3. You get a written answer. Loads with their basis, a scope letter or a sizing recommendation, and a budget range if you want one. Within one business day for questions; plan reviews are scheduled by size.
  4. Price it only if you want to. A consultation does not turn into a quote unless you ask. When you do, the engineering already matches your site, so the drawings get permitted and approved the first time.

Questions from architects, engineers and builders

Do you provide the structural engineering?

The building itself comes with stamped engineering from the manufacturer's engineers, licensed in all 50 states. HyperSteel buildings also include the foundation plan and anchors. For red iron Metallic buildings we provide the frame reactions and anchor bolt layout so your local engineer can design the foundation.

Will you review our drawings before we bid?

Yes. Send the architectural and structural sheets and the metal building spec section. We return a scope letter listing what the manufacturer includes, what is by others, and any conflicts we see, for example facade areas that need spandrel beams instead of girts, or openings that land in a braced bay.

Can you give us the snow load for a site in Utah?

Yes, for the exact lot, with the code basis (2024 IBC, ASCE 7-22 Risk Category II strength level, and the 0.7 factor for allowable stress comparison) and the building department's published value where one exists. The Utah loads page has city values and what changed in 2026.

Can we get panel samples and specifications?

Yes. We supply the manufacturer's panel profiles, gauges, finish warranties, color charts and specification sections, and can get physical panel and color samples for a project.

Are you a general contractor, erector, architect or engineering firm?

No. Tangent Steel Structures is a steel building supplier and authorized Metallic dealer. We supply the steel building package with the manufacturer's stamped engineering. Design, foundations, concrete, erection and site work are by the owner's architect, engineer, contractor and erector.

Do you work with our general contractor or erector?

Yes. We supply the building package with the manufacturer's engineering, coordinate delivery and sequencing with your GC, and can refer erectors in Utah and Idaho. Design-build teams and developers can send bid invites directly.